-<xsd:schema elementFormDefault="qualified" attributeFormDefault="unqualified" targetNamespace="http://www.prodml.org/schemas/1series" version="PRODML_v1.3">
<!--
                                                         
 -->
<!--
 Energistics License Agreement
	This file is distributed under the Energistics License Agreement at
	http://www.energistics.org
	Use of this file constitutes agreement with the Energistics License Agreement.
	Copyright (c) 2014 Energistics. All rights reserved.
	Energistics, WITSML, PRODML and RESQML are trademarks or registered trademarks of Energistics.
	
 -->
<!--
                                                         
 -->
 <xsd:include schemaLocation="typ_dataTypes.xsd"/>
 <xsd:include schemaLocation="typ_catalogProdml.xsd"/>
 <xsd:include schemaLocation="typ_dataTypesProdml.xsd"/>
 <xsd:include schemaLocation="typ_catalog.xsd"/>
 <xsd:include schemaLocation="cs_logData.xsd"/>
-<xsd:complexType name="cs_logDataInterpretation">
-<xsd:annotation>
 <xsd:documentation>Interpreted data in the form of a log of properties vs length along the facility (wellbore or pipeline).</xsd:documentation>
 </xsd:annotation>
-<xsd:complexContent>
-<xsd:restriction base="prodml:cs_logData">
-<xsd:sequence>
-<xsd:element name="mnemonicList" type="prodml:InterpretationMnemonicType" minOccurs="1" maxOccurs="1">
-<xsd:annotation>
 <xsd:documentation>The list of channels (ie, "columns") of data in the interpreted data object. This is a fixed list (enum). The list is in the form of comma separated names for the channels, e.g. "facilityDistance,adjustedTemperature,". These names are the mnemonics by which the channels are identified.</xsd:documentation>
 </xsd:annotation>
 </xsd:element>
-<xsd:element name="unitList" type="prodml:InterpretationUnitType" minOccurs="1" maxOccurs="1">
-<xsd:annotation>
 <xsd:documentation>The list of units of measure for the channels of data in the interpreted data object. This is a fixed list (enum). The list is in the form of comma separated units of measure for the channels, e.g. "m,degC,". These units of measure types are taken from the Energistics measureTypes.</xsd:documentation>
 </xsd:annotation>
 </xsd:element>
-<xsd:element name="data" type="xsd:string" minOccurs="0" maxOccurs="unbounded">
-<xsd:annotation>
 <xsd:documentation>Container for one "rows" of log data. It is in the form of comma separated values for the channels at this row, e.g. "100.0,75.5"</xsd:documentation>
 </xsd:annotation>
 </xsd:element>
 </xsd:sequence>
 </xsd:restriction>
 </xsd:complexContent>
 </xsd:complexType>
 </xsd:schema>