 edited with XMLSPY v5 rel. 4 U (http://www.xmlspy.com) 
 -->
-<xsd:schema targetNamespace="http://www.witsml.org/schemas/131" elementFormDefault="qualified" attributeFormDefault="unqualified" version="1.0">
<!--
                                                         
 -->
 <xsd:include schemaLocation="cs_wellNoticeAssociate.xsd"/>
 <xsd:include schemaLocation="cs_wellNoticeTwinWell.xsd"/>
 <xsd:include schemaLocation="cs_wellNoticeOtherInterest.xsd"/>
<!--
                                                         
 -->
-<xsd:complexType name="cs_wellNoticeCompliance">
-<xsd:sequence>
-<xsd:element name="highDensityArea" type="witsml:logicalBoolean" minOccurs="0" maxOccurs="1">
-<xsd:annotation>
 <xsd:documentation>If true, either there are more than 18 occupied buildings within 1,000 feet or the well is in a designated high-densityarea by order. If false, the area is not considered high density.</xsd:documentation>
 </xsd:annotation>
 </xsd:element>
-<xsd:element name="environmentallySensitiveArea" type="witsml:logicalBoolean" minOccurs="0" maxOccurs="1">
-<xsd:annotation>
 <xsd:documentation>If true, this location is in a Rule-designated environmentally sensitive area. If false, this location is not in a Rule-designated environmentally sensitive area.</xsd:documentation>
 </xsd:annotation>
 </xsd:element>
-<xsd:element name="applicableH2S" type="witsml:logicalBoolean" minOccurs="0" maxOccurs="1">
-<xsd:annotation>
 <xsd:documentation>If true, rules governing operations involving hydrogen sulfide are applicable. If false, hydrogen sulfide rules are not applicable,</xsd:documentation>
 </xsd:annotation>
 </xsd:element>
-<xsd:element name="deviation" type="witsml:WellNoticeWellDeviation" minOccurs="0" maxOccurs="1">
-<xsd:annotation>
 <xsd:documentation>A description of the wellbore path.</xsd:documentation>
 </xsd:annotation>
 </xsd:element>
-<xsd:element name="directionalSurveyPlanned" type="witsml:logicalBoolean" minOccurs="0" maxOccurs="1">
-<xsd:annotation>
 <xsd:documentation>If true, a directional survey is planned. If false, a directional survey is not planned.</xsd:documentation>
 </xsd:annotation>
 </xsd:element>
-<xsd:element name="maxPermittedDepth" type="witsml:measuredDepthCoord" minOccurs="0" maxOccurs="1">
-<xsd:annotation>
 <xsd:documentation>The maximum permitted depth for drilling. This information is used for bonding and compliance considerations and is NOT a proposed or an actual construction item.</xsd:documentation>
 </xsd:annotation>
 </xsd:element>
-<xsd:element name="siteInspection" type="witsml:logicalBoolean" minOccurs="0" maxOccurs="1">
-<xsd:annotation>
 <xsd:documentation>If true, site is ready for inspection. If false, the site is not ready for inspection.</xsd:documentation>
 </xsd:annotation>
 </xsd:element>
-<xsd:element name="unitGreater160Acres" type="witsml:logicalBoolean" minOccurs="0" maxOccurs="1">
-<xsd:annotation>
 <xsd:documentation>If true, the well is on a unit greater than 160 acres. If false, the well is not on a unit greater than 160 acres.</xsd:documentation>
 </xsd:annotation>
 </xsd:element>
-<xsd:element name="samplesRequired" type="witsml:logicalBoolean" minOccurs="0" maxOccurs="1">
-<xsd:annotation>
 <xsd:documentation>If true, samples are required. If false, samples are not required.</xsd:documentation>
 </xsd:annotation>
 </xsd:element>
-<xsd:element name="mudLogRequired" type="witsml:logicalBoolean" minOccurs="0" maxOccurs="1">
-<xsd:annotation>
 <xsd:documentation>If true, mud log is required. If false, a mud log is not required.</xsd:documentation>
 </xsd:annotation>
 </xsd:element>
-<xsd:element name="plugIntegrityTest" type="witsml:logicalBoolean" minOccurs="0" maxOccurs="1">
-<xsd:annotation>
 <xsd:documentation>If true, agency must witness the plug integrity test. If false, the agency does not need to witness the test.</xsd:documentation>
 </xsd:annotation>
 </xsd:element>
-<xsd:element name="dstRun" type="witsml:logicalBoolean" minOccurs="0" maxOccurs="1">
-<xsd:annotation>
 <xsd:documentation>If true, a drill stem test was run. If false, a drill stem test was not run.</xsd:documentation>
 </xsd:annotation>
 </xsd:element>
-<xsd:element name="bopTest" type="witsml:logicalBoolean" minOccurs="0" maxOccurs="1">
-<xsd:annotation>
 <xsd:documentation>If true, agency must witness the blowout preventer test. If false, the agency does not need to witness the test.</xsd:documentation>
 </xsd:annotation>
 </xsd:element>
-<xsd:element name="locationClearance" type="witsml:logicalBoolean" minOccurs="0" maxOccurs="1">
-<xsd:annotation>
 <xsd:documentation>If true, agency must witness the location clearance. If false, the agency does not need to witness the clearance.</xsd:documentation>
 </xsd:annotation>
 </xsd:element>
-<xsd:element name="mit" type="witsml:logicalBoolean" minOccurs="0" maxOccurs="1">
-<xsd:annotation>
 <xsd:documentation>If true, agency must witness the mechanical integrity test. If false, the agency does not need to witness the test.</xsd:documentation>
 </xsd:annotation>
 </xsd:element>
-<xsd:element name="gasStorageArea" type="witsml:logicalBoolean" minOccurs="0" maxOccurs="1">
-<xsd:annotation>
 <xsd:documentation>If true, well will be drilled within a gas storage field. If false, the well will not be drilled within a gas storage area.</xsd:documentation>
 </xsd:annotation>
 </xsd:element>
-<xsd:element name="gasStorageFieldOperator" type="witsml:cs_wellNoticeAssociate" minOccurs="0" maxOccurs="1">
-<xsd:annotation>
 <xsd:documentation>If well will be drilled in a gas storage area, contact information for the storage field operator.</xsd:documentation>
 </xsd:annotation>
 </xsd:element>
-<xsd:element name="injectionWellReservoir" type="witsml:logicalBoolean" minOccurs="0" maxOccurs="1">
-<xsd:annotation>
 <xsd:documentation>If true, the well will be drilled in a previous injection well area of review. If false, the well will not be drilled in a previous injection well area of review.</xsd:documentation>
 </xsd:annotation>
 </xsd:element>
-<xsd:element name="twin" type="witsml:cs_wellNoticeTwinWell" minOccurs="0" maxOccurs="unbounded">
-<xsd:annotation>
 <xsd:documentation>For a permit for a well "twinned" near an existing well, the existing well permit number and producing formation must be identified along with measures taken to ensure that the proposed twin well does not produce from the same zone as the existing well. </xsd:documentation>
 </xsd:annotation>
 </xsd:element>
-<xsd:element name="comment" type="witsml:commentString" minOccurs="0" maxOccurs="1">
-<xsd:annotation>
 <xsd:documentation>A comment relevant to regulatory compliance.</xsd:documentation>
 </xsd:annotation>
 </xsd:element>
 </xsd:sequence>
 </xsd:complexType>
<!--
                                                         
 -->
 </xsd:schema>